HPE FlexNetwork 5140 48G PoE+ 4SFP+ HI Switch
SKU: 0000705609
Kod producenta: R9L64A
HPE FlexNetwork 5140 48G PoE+ 4SFP+ HI Switch (R9L64A)
I/O ports and slots | 48 RJ-45 autosensing 10/100/1000 PoE+ ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T, IEEE 802.3at PoE+) | ||
4 SFP+ 10GbE ports 1 port expansion module slot | |||
Additional ports and slots | 1 dual-personality (RJ-45 or mini-USB) serial console port 1 RJ-45 out-of-band management port 1 USB 2.0 | ||
Power supplies | 2 power supply slots 1 minimum power supply required | ||
Fan tray | Airflow direction is from side to back | ||
Physical characteristics | Dimensions | 17.32(w) x 18.11(d) x 1.71(h) in. (44.00 x 46.00 x 4.36 cm) (1U height) | |
Weight | ≤9.6 kg | ||
Memory and processor | 2 GB SDRAM; Packet buffer size: 4 MB, 512 MB flash | ||
Mounting and enclosure | Mounts in an EIA standard 19-inch telco rack or equipment cabinet (hardwareincluded) | ||
Performance | 1000 Mb Latency | < 5 µs | |
10 Gbps Latency | < 3 µs | ||
Throughput | 180 Mpps | ||
Routing/Switching capacity | 336 Gbps | ||
Routing table size | 8K | ||
MAC address table size | 32K | ||
Environment | Operating temperature | 23°F to 113°F (-5°C to 45°C) | |
Operating relative humidity | 5% to 95%, noncondensing | ||
Non-operating/Storage temperature | -40°F to 158°F (-40°C to 70°C) | ||
Non-operating/Storage relative humidity | 5% to 95%, noncondensing | ||
Acoustic | Low-speed fan: 57.2 dB, High-speed fan: 68.9 dB; ISO 7779 | ||
Electrical characteristics | Frequency | 50/60 Hz | |
Maximum heat dissipation | ranges from 112 BTU/hr to 5943 BTU/hr depending on power supply configuration | ||
Voltage | 100-240 VAC, rated (90-264 VAC, max)-48 to -60 VDC, rated (-36 to -72 VDC, max) (depending on power supply chosen) | ||
Maximum power rating | 1742 W (dual AC) | ||
Idle power | 40 W (dual AC) | ||
PoE power | 1440W (30W max PoE power per port) | ||
Notes: | - Idle power is the actual power consumption of the device with no ports connected. - Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated - PoE+ power range is from 360W to 1440W. PoE+ power is the power supplied by the internal power supplies. It is dependent on the type and quantity of power supplies. Device supports 1 or 2 internal modular power supplies. | ||
Safety | UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-Part 2; IEC 60950-1; EN 60950-1; CAN/CSA-C22.2 No. 60950-1; FDA 21 CFR Subchapter J; RoHS Compliance; AS/NZS 60950-1; GB 4943; EAC (EurAsian Conformity Certification) | ||
Emissions | ETSI EN300 386 V1.6.1 (2012-09); ETSI EN 300 386 V2.1.1 (2016-07); EN 55032:2015 CLASS A; CISPR 32:2015 CLASS A; AS/NZS CISPR 32:2015 CLASS A; EN 61000-3-2:2014; EN 61000-3-3:2013; FCC PART15 Subpart B CLASS A; ICES-003 Issue 7 CLASS A; ANSI C63.4-2014; VCCI-CISPR 32:2016 CLASS A | ||
Generic | IEC 61000-4-1:2006; IEC 61000-4-2:Ed2 2008; IEC 61000-4-3:2020; IEC 61000-4-3:2010; IEC 61000-4-4:2004; IEC 61000-4-4:2011; IEC 61000-4-4:Ed3.0 2012; IEC 61000-4-5:2014; IEC 61000-4-5:2017; IEC 61000-4-6:2013; IEC 61000-4-6:2013 COR1:2015; IEC 61000-4-8:2009; IEC 61000-4-11:2004; IEC 61000-4-11:2017; IEC 61000-4-11:2020 | ||
ESD | Air 8KV; Con 6KV; Criteria B | ||
Immunity | ETSI EN300 386 V1.6.1 (2012-09); ETSI EN 300 386 V2.1.1 (2016-07); EN 55035:2017; CISPR 35:2016; | ||
Management | IMC-Intelligent Management Center; Smart MC, command-line interface; SNMP Manager | ||
Services | Refer to the Hewlett Packard Enterprise website at: http://www.hpe.com/networking/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local Hewlett Packard Enterprise sales office. |
Opis
- Gwarancja zewnętrzna
- -1
- Wymiary
- 440.0 x 460.0 x 43.6 mm
- Waga
- 9.6
- Typ obudowy
- Rack
- Wentylator
- Tak
- Zasilanie
- 100240 VAC
maks.) -48 do -60 VDC
max) (w zależnoÅci od wybranego źródÅa zasilania)
znamionowe (-36 do -72 VDC
znamionowe (90264 VAC - Zastosowanie
- Średnie i duże firmy
- Klasa przełącznika
- Zarządzalny
- Architektura sieci
- GigabitEthernet
- Liczba portów 10/100/1000 Mbps
- 48
- Obsługiwane protokoły i standardy
- IEEE 802.1AE MACsec
IEEE 802.1AX2008 Link Aggregation
IEEE 802.1D MAC Bridges
IEEE 802.1Q (GVRP)
IEEE 802.1Q VLANs
IEEE 802.1X PAE
IEEE 802.1ad Q-in-Q
IEEE 802.1ak Multiple Registration Protocol (MRP) and Multiple VLAN Registration Protocol (MVRP)
IEEE 802.1p Priority
IEEE 802.1s Multiple Spanning Trees
IEEE 802.1v VLAN classification by Protocol and Port
IEEE 802.1w Rapid Reconfiguration of Spanning Tree
IEEE 802.3 Medium Attachment Units (MAUs)
IEEE 802.3 Type 10BASE-T
IEEE 802.3ab 1000BASE-T
IEEE 802.3ac (VLAN Tagging Extension)
IEEE 802.3ad Link Aggregation (LAG)
IEEE 802.3ad Link Aggregation Control Protocol (LACP)
IEEE 802.3ae 10-Gigabit Ethernet
IEEE 802.3af Power over Ethernet
IEEE 802.3at Power over Ethernet Plus
IEEE 802.3az Energy Efficient Ethernet
IEEE 802.3i 10BASE-T
IEEE 802.3u 100BASE-X
IEEE 802.3x Flow Control
IEEE 802.3z 1000BASE-X RFC 768 UDP
RFC 783 TFTP Protocol (revision 2)
RFC 791 IP
RFC 792 ICMP
RFC 793 TCP
RFC 826 ARP
RFC 854 TELNET
RFC 855 Telnet Option Specification
RFC 894 IP over Ethernet
RFC 925 Multi-LAN Address Resolution
RFC 950 Internet Standard Subnetting Procedure
RFC 951 BOOTP
RFC 959 File Transfer Protocol (FTP)
RFC 1027 Proxy ARP
RFC 1042 IP Datagrams
RFC 1058 RIPv1
RFC 1071 Computing the Internet Checksum
RFC 1122 Requirements for Internet HostsCommunication Layers
RFC 1123 Requirements for Internet Hosts
RFC 1141 Incremental updating of the Internet checksum
RFC 1166 IP Addresses
RFC 1191 Path MTU discovery
RFC 1213 Management Information Base for Network Management of TCP/IP-based internets
RFC 1256 ICMP Router Discovery Protocol (IRDP)
RFC 1305 NTPv3
RFC 1350 TFTP Protocol (revision 2)
RFC 1519 CIDR
RFC 1533 DHCP Options and BOOTP Vendor Extensions
RFC 1542 BOOTP Extensions
RFC 1591 DNS (client only)
RFC 1643 Definitions of Managed Objects for the Ethernet-like Interface Types
RFC 1723 RIP v2
RFC 1812 IPv4 Routing
RFC 1866 Hypertext Markup Language2.0
RFC 1887 An Architecture for IPv6 Unicast Address Allocation
RFC 1901 Introduction to Community-based SNMPv2
RFC 1902-1907 SNMPv2
RFC 2131 DHCP
RFC 2236 IGMP Snooping
RFC 2375 IPv6 Multicast Address Assignments
RFC 2462 IPv6 Stateless Address Autoconfiguration
RFC 2474 Definition of the Differentiated Services Field (DS Field) in the IPv4 and IPv6 Headers
RFC 2475 Architecture for Differentiated Services
RFC 2597 Assured Forwarding PHB Group
RFC 2616 Hypertext Transfer ProtocolHTTP/1.1
RFC 2644 Directed Broadcast Control
RFC 2665 Definitions of Managed Objects for the Ethernet-like Interface Types
RFC 2668 Definitions of Managed Objects for
RFC 2711 IPv6 Router Alert Option
RFC 2865 Remote Authentication Dial In User Service (RADIUS)
RFC 2866 RADIUS Accounting
RFC 2868 RADIUS Attributes for Tunnel Protocol Support
RFC 3046 DHCP Relay Agent Information Option
RFC 3246 Expedited Forwarding PHB
RFC 3410 Applicability Statements for SNMP
RFC 3414 User-based Security Model (USM) for version 3 of the Simple Network Management Protocol (SNMPv3)
RFC 3415 View-based Access Control Model (VACM) for the Simple Network Management Protocol (SNMP)
RFC 3416 Protocol Operations for SNMP
RFC 3417 Transport Mappings for the Simple Network Management Protocol (SNMP)
RFC 3418 Management Information Base (MIB) for the Simple Network Management
RFC 3484 Default Address Selection for Internet Protocol version 6 (IPv6)
RFC 3493 Basic Socket Interface Extensions for IPv6
RFC 3542 Advanced Sockets Application Program Interface (API) for IPv6
RFC 3576 Ext to RADIUS (CoA only)
RFC 3580 IEEE 802.1X Remote Authentication Dial In User Service (RADIUS) Usage Guidelines
RFC 3587 IPv6 Global Unicast Address Format
RFC 3596 DNS Extensions to Support IP Version 6
RFC 3704 Unicast Reverse Path Forwarding (URPF)
RFC 4113 Management Information Base for the User Datagram Protocol (UDP)
RFC 4213 Basic IPv6 Transition Mechanisms
RFC 4250 The Secure Shell (SSH) Protocol Assigned Numbers
RFC 4251 The Secure Shell (SSH) Protocol Architecture
RFC 4252 The Secure Shell (SSH) Authentication Protocol
RFC 4253 The Secure Shell (SSH) Transport Layer Protocol
RFC 4254 The Secure Shell (SSH) Connection Protocol
RFC 4291 IP Version 6 Addressing Architecture
RFC 4443 Internet Control Message Protocol (ICMPv6) for the Internet Protocol Version 6 (IPv6) Specification
RFC 4541 Considerations for Internet Group Management Protocol (IGMP) and Multicast Listener Discovery (MLD)
RFC 4594 Configuration Guidelines for DiffServ Service Classes
RFC 4675 RADIUS VLAN & Priority
Snooping Switches - Rozmiar tablicy adresów MAC
- 32000
- Obsługa ramek Jumbo
- Tak
- Warstwa przełączania
- L2
- Zasilacz
- Wewnętrzny
- Przepustowość
- 336
- Liczba portów 10Gb
- 4
- Port konsoli
- Tak
- Zarządzanie, monitorowanie, konfiguracja
- Advertises and receives management information from adjacent devices on a network
Command authorization:
Complete session logging:Â
Enables configuration and management through a secure CLI located on a remote device
IEEE 802.1AB Link Layer Discovery Protocol (LLDP):Â
Leverages RADIUS/HWTACACS to link a custom list of CLI commands to an individual network administrator\'s login, also provides an audit trail
Management VLAN:Â
Manager and operator privilege levels:Â
Multiple configuration files:Â
Provides detailed information for problem identification and resolution
Provides read-only (operator) and read/write (manager) access on CLI management interfaces
Remote configuration and management:Â
Remote monitoring (RMON):Â
Segments traffic to and from management interfaces
Stores easily to the flash image
Uses standard SNMP to monitor essential network functions, supports events
alarm
and statistics group plus a private alarm extension group
facilitating easy mapping by network management applications
history
including CLI/Telnet and SNMP
sFlow (RFC 3176):Â - Bezpieczeństwo
- IEEE 802.1X Port Based Network Access Control
RFC 1492 TACACS+
RFC 2138 RADIUS Authentication
RFC 2139 RADIUS Accounting
RFC 2865 RADIUS Authentication
RFC 2866 RADIUS Accounting
RFC 3260 New Terminology and Clarifications for DiffServ
RFC 4716 SSH Public Key File Format
Secure Sockets Layer (SSL) SSHv2 Secure Shell - Liczba portów SFP+
- 4
- Prędkość przekazywania
- 180
- Bufor pakietów
- 4
- Rozmiar ramki Jumbo
- 8
- QoS
- RFC 2474 DS Field in the IPv4 and IPv6 Headers
RFC 3260 New Terminology and Clarifications for DiffServ - Funkcje L3
- Address Resolution Protocol (ARP):Â
Allows UDP broadcasts to be directed across router interfaces to specific IP unicast or subnet broadcast addresses and prevents server spoofing for UDP services such as DHCP
Centralizes and reduces the cost of IPv4 address management
DHCP server:Â
Defines an address that can always be reachable
Determines the MAC address of another IP host in the same subnet, supports static ARPs, gratuitous ARP allows detection of duplicate IP addresses, proxy ARP allows normal ARP operation between subnets or when subnets are separated by a Layer 2 network
Dynamic Host Configuration Protocol (DHCP):Â
Loopback interface address:Â
Policy Based Routing\"Â
Provide more control during route redistribution, allow filtering and altering of route metrics
Provides a mechanism for indicating and executing forwarding/routing of data packets based on the policies defined by the network administrator
Route maps:Â
Simplifies the management of large IP networks, supports client, DHCP Relay enables DHCP operation across subnets
User Datagram Protocol (UDP) helper function:Â
improving diagnostic capability - Liczba portów PoE+
- 48
Producent HP Inc. Building 4, 1501 Page Mill Rd CA 94304 Palo Alto Stany Zjednoczone support@hp.com 650-324-3125
Osoba odpowiedzialna HP Inc Polska sp. z o.o. Plac Marszałka Józefa Piłsudskiego 1 00-078 Warszawa Polska support@hp.com +48 22 50 20 670